Include backup power and communications in the quote
Backup power and a backup communications link serve different purposes. Ask for a price that includes the control panel battery, power for the other equipment the alarm needs, a mobile connection and the service that goes with it. If a cheaper quote leaves any of these out, it covers less.
Check detection, the siren and the alert
An alarm system has detectors, a control panel, warning devices and communications links. Some components have their own batteries. Others draw power from the panel or from a separate supply. Losing power at one socket need not stop everything at once.
If your router loses power, the control panel may keep running on its battery. The detectors and siren may still work, but any alert that relies on the router has lost its usual route. The reverse is also possible. You may still be able to open the app on your phone even though a device at home is offline. The app alone cannot tell you that everything is working.
When choosing a home alarm, ask the installer to explain the whole chain. Which device detects the intrusion, which decides whether to raise the alarm, which sends the alert and who handles it? The answer should describe the equipment in your quote, rather than the manufacturer’s entire range.
What the control panel battery keeps running
Battery life depends on the model, the battery’s charge and condition, and how it was tested. Ask which communications links and accessories stay powered and whether the system uses a power-saving mode. You need these details to compare the backup times quoted for two systems.
Ask about the batteries in the panel, detectors and sirens separately. Check any external equipment the system needs, such as a router, fibre converter, repeater or camera power supply. An uninterruptible power supply can keep some devices running. It cannot fix an outage on the provider’s network.
The maintenance contract should say who checks and replaces batteries and how a fault is reported. A battery fitted today may no longer give the expected running time several years later. Both wired and wireless alarms rely on electrical power, so check the backup arrangements for either type.
Do your internet and mobile connections use separate routes?
Ethernet and Wi-Fi may use the same router and internet connection. Using both offers no protection if that shared connection fails. A mobile link gives the alarm another route, provided it is enabled, there is coverage at the control panel and the contract includes it.
The number of SIM slots alone tells you neither how many routes are active nor how the system switches between them. Ask which networks it uses, who pays for the connection and how the system reports faults. For example, Ajax’s support documentation lists the interfaces available on different control panels. Check which of them your installation and subscription actually use.
Two routes can still depend on the same equipment or service. Several local connections are of little use if the devices at either end lose power or a remote service they need goes offline. Ask which functions will still work in each case.
How the system detects a lost connection
The system can check at intervals whether a device or link is responding and report a lost connection even when there has been no intrusion. The time it takes to detect a fault is separate from the time needed to send an alarm or for someone to reach the property.
Evalink’s technical documentation on EN 50136 distinguishes failure of the main transmission path from loss of all paths at once. Its DP4 table gives a maximum reporting time of 90 seconds for the main path and 3 minutes if all paths fail. Those figures describe fault reporting. They do not say when help will arrive.
The quote should make this distinction clear. If it promises ‘dual-path signalling’, ask who will notice a fault, how soon and what they will do next. The system settings must match the arrangements at the alarm receiving centre.
A checklist for the installer at handover
Ask the installer to fill in the table for the model and configuration you actually receive. For each ‘yes’, ask which function works and how to check it. Resolve any unknowns before accepting the installation.
On a small screen, scroll the table horizontally.
| Test scenario | What to record | Evidence to ask for |
|---|---|---|
| Loss of mains power | Functions that keep working and documented battery life | Instructions and a supervised switchover test |
| Loss of the home’s internet connection | Local detection and remaining transmission path | Alert received by the intended recipient |
| Mobile transmission path unavailable | Remaining transmission path and fault notification | Event identified in the report |
| Loss of all transmissions | Local warning and remote monitoring of the connection | How quickly a lost connection is detected and what happens next |
| Return to normal operation | Reconnection, battery recharging and notification that service is restored | Check that the system is back to normal |
Signal jamming differs from an ordinary internet outage. Ask what the equipment can detect and how it handles a fault. A jamming detection feature does not guarantee that all communications will get through in every situation.
Test with the installer and whoever receives the alert
Plan the tests with your service provider and, if the system is connected to one, the alarm receiving centre. Agree when the test will take place, which events to expect and how to return the system to service. Never ring the police emergency number to test a button or an alert, or try to jam the signal.
The test report should record what was simulated, what still worked, which alerts were received and what needs putting right. It should also confirm that the system returned to normal. Sounding the siren alone tells you much less.
If you pay for monitoring, ask for the contract to spell out who maintains the equipment and deals with faults. This lets you distinguish what the equipment can do, which features are switched on and which services you are paying for.
Sources and references
These are the documents used in this guide.
- Ajax support documentation Manufacturer’s documentation. It covers the products and services described.
- Evalink’s technical documentation on EN 50136 Manufacturer’s documentation. It covers the products and services described.