How the product affects the price
There is no fixed price increase for moving up an RC class. The dimensions, materials, installation and configuration tested all affect the cost. Compare the certificate with the exact model and specification in the quote.
What does “RC” mean?
RC stands for ‘resistance class’. Classification involves mechanical resistance tests and, for certain classes, a manual attack test using specified tools. EN 1628, EN 1629 and EN 1630 describe the test methods. A rating applies to the complete door, window or other assembly in the configuration tested, including its lock.
The table gives the resistance times for manual attack tests reported by Buildwise. Active attack time is only part of the total test time.
On a small screen, scroll the table horizontally.
| Class | Resistance time in the manual attack test | How to interpret it |
|---|---|---|
| RC1N | No manual attack test of this kind | Entry-level class assessed without the manual attack test used for higher classes |
| RC2N / RC2 | 3 minutes | Test with a specified set of simple tools |
| RC3 | 5 minutes | A more demanding tool set than for RC2 |
| RC4 | 10 minutes | Higher class with a different tool set |
| RC5 | 15 minutes | Test includes power tools |
| RC6 | 20 minutes | The highest level of this classification |
These times come from a repeatable test. How long an assembly resists in practice depends on the condition of the supporting structure, the installation, how the opening is secured and the tools used. An RC3 rating cannot guarantee five minutes of resistance at home.
How RC2 and RC2N differ on glazing
The letter N matters. RC2N does not impose the same requirement for burglar-resistant glazing as RC2. Two windows advertised as “level 2” may therefore differ. If the glazing is accessible, specifically ask for the rating of the whole assembly and the glazing specification covered by that rating.
The Hanover police guidance identifies the classes that allow unprotected glazing. Ask for the full class designation in the quote. A single letter can change the specification.
What should the document cover?
Door models come in different sizes, opening directions and hardware configurations. Check which versions the classification document covers. An optional fitting may fall outside its scope. Bern University of Applied Sciences describes how these building components are tested.
Ask for the classification document for the exact model offered and the installation instructions. Check which supporting structure, fixings, clearances and components they allow. A result for one configuration may not apply to another.
Naming a standard does not establish that a product is certified. A classification describes performance against specified criteria. Certification adds an assessment and follow-up process set by the certification body. Ask whether the supplier has a test report, a classification or a certificate.
This check also matters when choosing a window security grille or components for a safe room. Evidence for one component does not establish the performance of the whole assembly.
Choosing a class for each entry point
Start with the entry points and circumstances that matter to you. These might include an easily reached window, a secluded side door, people at home overnight, insurance requirements or a specific threat. Ask the installer to propose a class, document it and explain the choice alongside the measures proposed for other openings.
Worked example. Two quotes specify an RC3 front door. One leaves a damaged service door in place. The other repairs that door and improves the locking on a glazed opening. The same front-door rating gives different results for the home as a whole. Compare all the routes into the building covered by the assessment.
A higher class can mean a heavier, thicker assembly, greater demands on the supporting structure and a higher cost. Ask how that class addresses your particular need. When choosing a door for a refuge area, for example, you also need to consider who will use it, how they can escape and how they can raise the alarm.
How RC classes, glazing ratings and certification differ
EN 356 classifies security glazing. EN 1627 classifies complete construction elements. National doorset certification schemes, where available, apply to a specified product. These references describe different objects and assessment procedures; matching numbers or test times do not make them interchangeable.
When reviewing a quote, ask: ‘Which document shows how the complete assembly performs in the configuration you plan to install?’ Look for an identifiable product and supporting evidence. Descriptions such as ‘reinforced’, ‘high security’ and ‘professional’ give you nothing to verify.
Sources and references
These are the documents used in this guide.
- Buildwise The performance figures apply to the product or configuration described in the document.
- Hanover police guidance on classes with unprotected glazing Source for the explanations and steps in this guide.
- Bern University of Applied Sciences The performance figures apply to the product or configuration described in the document.